Conductive Bead Curtain Anti-static Fiber Woven Rope High Performance Door Curtain
|
|
Material:
|
Stainless Steel
|
Wearing ropes:
|
25 pieces
|
Size:
|
110*90cm or Customized Sizes
|
Diameter:
|
6mm
|
Spacing:
|
110cm
|
Structure:
|
stainless steel door beam+copper terminals+bell buckle+anti-static rope
|
Applicable scope:
|
1. Anti static rope, also known as anti-static rope, is a material that can release charges when grounded or connected to any lower potential point. It is divided into conductive and electrostatic discharge types based on the surface resistance value.
2.According to different environments, anti-static ropes have different products and specifications to meet their purpose of preventing static electricity. They can effectively prevent and combat the existence of static electricity, reduce the harm caused by static electricity, and have a wide range of applications, such as microelectronics industry, computers, communication and electronic equipment, manufacturing equipment, textile machinery, hospital operating rooms, anesthesia rooms, oxygen bars, etc., especially for some factories, electronic factories, computer rooms, etc, Due to the presence of a large amount of static electricity in its surrounding environment, static electricity can cause some harm to the surrounding electronic products. 3. Not only does it cause harm to machines and instruments, but excessive static electricity is also a danger to the human body. Therefore, releasing static electricity has become an indispensable part of important areas such as medical and health care, electronic factories, and computer rooms. People should be prepared for anti-static measures from the moment they enter, so anti-static door curtains have emerged. The anti-static ability is reflected by the electrical resistivity. The lower the electrical resistivity, the easier it is to release static electricity, and the better the anti-static effect! The surface resistance of ordinary fabrics is around 10 to the 9th power, which almost cannot achieve the function of anti-static. 4. The anti-static rope is woven from a blend of metal fibers and polyester fibers, with a stable surface resistance of 10 to the power of 3, and can withstand water washing and pollution. Therefore, its conductivity effect is obvious and static electricity is fully released. When you pass through the anti-static door curtain, the static electricity carried and stored on your body will be completely released by the anti-static door curtain rope through grounding. Give you a clean and safe working environment. |
Method of making anti-static rope door curtains:
|
1.The width and height of the inner door should be measured to calculate the total length of the rope required. The calculation basis is: the spacing between each rope of the anti-static door curtain is 2m-10m (usually 5m), and the length should be around 1 meter above the ground after hanging.
2. Cut the rope section by section according to the required length, and then fix both ends of the cut rope with suitable copper terminals (one end can also be fixed with copper terminals, and the other end can be fixed with a dedicated copper pendant or directly knotted). 3. Cut aluminum alloy profiles or copper plates with grooves according to the width of the door, press the copper terminal at one end of the prepared anti-static rope into the aluminum alloy groove "Copper plate needs to be drilled and fixed", and fix the copper plate according to the selected spacing. 4. Fix the aluminum alloy pipe or copper plate with ropes installed above the door frame, and ground one end of the aluminum alloy pipe or copper plate. |
Performance of anti-static rope:
|
1. Electric rope structure: The outer layer is interwoven with black, white, and green colored fibers, and the inner layer is wrapped with white yarn.
2. Performance: The anti-static rope can be made into an anti-static door curtain, which has the function of discharging static electricity. It has good conductivity and can instantly introduce static electricity into the ground in an
uncharged state. 3. Usage: Fix and hang one by one at the entrance of personnel entry and exit. When personnel enter and exit, they come into contact with the anti-static rope, and use the anti-static rope to guide away static electricity from the human body, thereby eliminating static electricity from the human body and achieving good anti-static effect. 4. Surface resistance: 10 ^ 52-10 ^ 7 see. 5. Common specifications: diameter 4mm, 6mm, 8m, etc., 50m/roll or 100m/roll. |
Method of making anti-static rope door curtains:
|
1.The width and height of the inner door should be measured to calculate the total length of the rope required. The calculation basis is: the spacing between each rope of the anti-static door curtain is 2m-10m (usually 5m), and the length should be around 1 meter above the ground after hanging.
2. Cut the rope section by section according to the required length, and then fix both ends of the cut rope with suitable copper terminals (one end can also be fixed with copper terminals, and the other end can be fixed with a dedicated copper pendant or directly knotted). 3. Cut aluminum alloy profiles or copper plates with grooves according to the width of the door, press the copper terminal at one end of the prepared anti-static rope into the aluminum alloy groove "Copper plate needs to be drilled and fixed", and fix the copper plate according to the selected spacing. 4. Fix the aluminum alloy pipe or copper plate with ropes installed above the door frame, and ground one end of the aluminum alloy pipe or copper plate. |