Customization: | Available |
---|---|
Usage: | SMT Production Line, Printing Workshop, Computer Room, Electronic Component Maintenance Room, Combustible & Explosive Area |
Input Voltage: | DC24V±5% |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameters | ||
Input voltage | DC24V±5% | |
Iron generating way | Corona discharge way | |
Display LED | H.V(green) | High voltage normal operation indicator light is on |
ALARM (red) | The indicator light is on when discharge is abnormal and electric circuit is abnormal; | |
CLEANIKIG (yellow) | The indicator is on and the buzzer prompts when reaching the set cleaning time. | |
Voltage regulation mode/ applied voltage | High frequency AC way/±2200V | |
Ion balance | Within ±20 V(measuring distance 300mm,supply air pressure 0.3MPa) | |
Destaticizing time | 2.0S(measuring distance 300mm, supply air pressure 0.3MPa) | |
Cleaning timer set time | Can be set within 0-999 hours | |
Ozone generation amount(ppm ) | Within 0.03pp m(measuring distance 50mm,supply air pressure 0.2MPa ) | |
Applicable fluid | Air(cleaning air of which the water and oil has been removed) | |
Air pressure application range(MPa) | 0.01-0.5MPa | |
Use ambient temperature | Indoor 0~40ºC CM0T | |
Use ambient humidity | 15~75%Rh (no condensation) |